Share  
Print  
New
MERSEN

Mersen Fuse: 7 A, 250V Ac, 2 In L X 9/16 In Dia Fuse Size, Cylindrical Body, Tr-R

Hover over image to magnify
Fuse,Class RK5,7A,Tr-R Series
Fuse,Class RK5,7A,Tr-R Series

#941751-1 | Pkg Qty: 1

$12.03 pkg | $12.03 ea

Drop Ship Item

Shipping to 60045

Technical Specifications

Key Specifications
AC Voltage Rating
250VAC
Interrupt Rating
200kA at 250VAC, 20kA at 160VDC
Body Material
Polyester
Item
Fuse
Body Style
Cylindrical
Length
2 in.
Brand
MERSEN
Mfr. Part Number
TR7R
Class
RK5
Package Quantity
1
DC Voltage Rating
160VDC
Series
TR-R
Diameter
9/16 in.
Shipping Weight
.04 lb.
Element
Dual
Speed
Time Delay
General
Amps
7 A
Fits Fuse Block Style
Rejection
Compatible Fuse Block Series
2HKRFB
Fuse Size
2 in L x 9/16 in dia
Equivalent Brand and Series
Bussmann FRN-R, Edison ECNR, Littelfuse FLNR, Mersen TR-R
Standards
CSA, UL
Equivalent Series
ECNR, FLNR, FRN-R, TR-R
Visual Indication
Nonindicating

Product Description

These 250VAC UL Class RK5 fuses are time delay and nonindicating. They tolerate temporary inrush currents without opening, which prevents nuisance-blowing from motor and equipment startups. Also called slow-blow Class RK5 fuses, these 200kA IR fuses open to disconnect an electrical circuit when exposed to sustained loads and short circuits. They have no indicator for identifying a blown fuse, so they're sometimes used with an indicating fuse block or cover.

UL Class RK5 fuses provide moderate current limitation for general use applications where more current-limiting RK1 fuses aren't needed. These fuses have an interrupting rating (IR) of 200kA and are the same size as Class H and K fuses, but have a rejection feature that prevents an accidental downgrade from a current-limiting system. Their modified terminals ensure a match with the rejection clips in Class R fuse holders that prevent the installation of fuses with a lower interrupting capacity. They're typically used in newer equipment, but can also be used with a Class H fuse holder to upgrade older installations from Class H or K fuses for improved overcurrent protection. They are current-limiting to prevent electrical damage by disconnecting circuits before they're exposed to the full magnitude and duration of an overcurrent.

Item Barcode
9417511
Fuse,Class RK5,7A,Tr-R Series
 NameItemDescription
Grainger DropshipGrainger Dropship4TCP6
UNSPSC CODESUNSPSC CODES39121604
VMRS (ATA) CODESVMRS (ATA) CODES053-006-009

For more product information by email, click here