EATON BUSSMANN

Eaton Bussmann 3-Pole Industrial Fuse Block, AC: 600 VAC, DC: 300 VDC, 110 to 200A, Series FRN, FRS, KTN-R, KTS-R, LP

Hover over image to magnify
Fuse Block,Industrial,200A,3
Fuse Block,Industrial,200A,3

#930478-6 | Pkg Qty: 1

$958.93 pkg | $958.93 ea

Drop Ship Item

Shipping to 60045

Technical Specifications

Key Specifications
AC Voltage Rating
600 VAC
Fuse Type
Industrial
Amp Range of Fuse Block or Holder
110 to 200A
Fuse UL Class
R
Amps AC
110 to 200
Height
3.8 in.
Body Material
Thermoplastic
Indicating / Nonindicating
Nonindicating
Brand
EATON BUSSMANN
Item
Fuse Block
Connector Type
Box Lug
Length
11.2 in.
DC Voltage Rating
300 VDC
Mfr. Part Number
RM60200-3CR
Depth
3 in.
Mounting Style
Bolt-Down; DIN Rail
For Fuse Series
FRN, FRS, KTN-R, KTS-R, LPN, LPS
Number of Poles
3
For Fuse Size
7-1/8 in. L x 1-9/16 in. dia
Package Quantity
1
Fuse Block Design
Open
Series
Rm
Fuse Block/Fuse Holder Type
Fuse Block
Shipping Weight
3.55 lb.
Fuse Block/Holder AC Voltage Rating
600 VAC
Voltage Rating
600 VAC/300 VDC
Fuse Block/Holder DC Voltage Rating
300 VDC
Width
2.61 in.
Fuse Dimensions
11-13/64 in.L x 3-51/64 in.H x 2-39/64 in.W
Wire Range
6 AWG to 250 MCM
Fuse Holder Code
S
Wire Size
6 AWG to 250 MCM
Fuse Length
9-3/5 in.
General
Amp Range
101 to 200 A
Fuse Block or Fuse Holder Type
Fuse Block
Compatible Fuse Series
A6D-R, A6K-R, FRS-R, KLSR, KTS-R, KWS-R, LLSRK, LPS-RK, TRS-R
Fuse Block or Holder AC Voltage Rating
600VAC
Features
Short Circuit and Overload Protection
Fuse Block or Holder DC Voltage Rating
300VDC
Fits Fuse Type
Industrial
Standards
CSA Certified
For Use With
FRS-R; KTS-R; KWS-R; PVS-R; LPS-RK
Visual Indication
Nonindicating
Fuse Block Style
Rejection

Product Description

These fuse blocks are compatible with UL Class RK1 and RK5 fuses. They are rejection-style blocks with clips that fit the modified terminals of Class R fuses to prevent the installation of fuses with a lower voltage rating or interrupting capacity. They're used with RK1 fuses to provide high current limitation for applications where a fast response to overcurrent is required. They're used with Class RK5 fuses to provide moderate current limitation for general use applications.

UL Class and midget fuse blocks accept fuses sized and rated according to UL Class or midget specifications. They have an open top for access to fuses, clips or studs for securing fuses within the block, and terminals for connecting to the circuit. These fuse blocks are either bolted down or mounted on a DIN rail to hold them in place. They're commonly paired with fuse box covers to enclose the fuses and prevent accidental contact. They are nonindicating, so there's no visual signal when a fuse is blown.

Expertly Selected Product Pairings

Fuse Cover,110 To 200A,H,RK5,
$89.83 pkg | $89.83 ea
Item: 926221-6 | Pkg Qty: 1
Fuse Cover,110 To 200A,H,RK5,
$126.97 pkg | $126.97 ea
Item: 926221-7 | Pkg Qty: 1

Item Barcode
9304786
Fuse Block,Industrial,200A,3
 NameItemDescription
Grainger DropshipGrainger Dropship39P383Fuse Block, Industrial,
UNSPSC CODESUNSPSC CODES39121629
VMRS (ATA) CODESVMRS (ATA) CODES053-006-009Fuse Block, Industrial,

For more product information by email, click here