Share  
Print  
BUSSMANN

50A Time Delay Melamine Fuse with 250VAC/125VDC Voltage Rating; LPN-RK-SP Series

Hover over image to magnify
Fuse,RK1,Lpn-Rk-Sp,50A,250VAC/
Fuse,RK1,Lpn-Rk-Sp,50A,250VAC/

#921446-7 | Pkg Qty: 1

$33.48 pkg | $33.48 ea

Drop Ship Item

Shipping to 60045

Technical Specifications

Key Specifications
AC Voltage Rating
250 VAC
Indicating
No
Amperage
50 A
Indicating / Nonindicating
Nonindicating
Body Material
Melamine
Interrupt Rating
300kA at 250VAC, 100kA at 125VDC
Body Style
Cylindrical
Item
Fuse
Brand
BUSSMANN
Length
3 in.
Class
RK1
Mfr. Part Number
LPN-RK-50SP
DC Voltage Rating
125 VDC
Package Quantity
1
Diameter
13/16 in.
Rejection / Nonrejection
Rejection
Element
Dual
Series
Lpn-Rk-Sp
Functionally Equal To
Mersen/Ferraz Shawmut A2D-R, Littelfuse LLNRK
Shipping Weight
.1 lb.
Fuse Amps
50A
Speed
Time Delay
Fuse Holder Code
K
Type
Low Voltage
Fuse Speed
Time Delay
Voltage Rating
250 VAC/125 VDC
Fuse Voltage Rating
250 VAC/125 VDC
General
Compatible Fuse Block Series
HM600, R250
Fuse Size
3 in L x 13/16 in dia
Equivalent Series
A2D-R, LLNRK, LPN-RK-SP
Standards
CE, UL Special Purpose Guide JFHR, Guide JDDZ, File E4273, CSA Class 1422-02, File 53787, CSA C22.2, No. 248.12
Fits Fuse Block Style
Rejection
Visual Indication
Nonindicating

Product Description

Time-delay, nonindicating UL Class RK1 fuses tolerate temporary inrush currents without opening, which prevents nuisance-blowing from motor and equipment startups. Also called slow-blow Class RK1 fuses, they open to disconnect an electrical circuit when exposed to sustained loads and short circuits. They have no indicator for identifying a blown fuse, so they're sometimes used with an indicating fuse block or cover.

UL Class RK1 fuses are more current-limiting than RK5 fuses to react more quickly to overcurrent. These fuses are the same size as Class H and K fuses, but have a rejection feature that prevents an accidental downgrade from a current-limiting system. Their modified terminals ensure a match with the rejection clips in Class R fuse holders that prevent the installation of fuses with a lower interrupting capacity. They're typically used in newer equipment, but can also be used with a Class H fuse holder to upgrade older installations from Class H or K fuses for improved overcurrent protection. These fuses are current-limiting to prevent electrical damage by disconnecting circuits before they're exposed to the full magnitude and duration of an overcurrent.

Expertly Selected Product Pairings

Puller,Fuse,Medium
$45.12 pkg | $45.12 ea
Item: 915926-8 | Pkg Qty: 1

Item Barcode
9214467
Fuse,RK1,Lpn-Rk-Sp,50A,250VAC/
 NameItemDescription
Grainger DropshipGrainger Dropship4XF57Fuse,RK1,LPN- RK-SP,50A,
UNSPSC CODESUNSPSC CODES39121604
VMRS (ATA) CODESVMRS (ATA) CODES053-006-009Fuse,RK1,LPN- RK-SP,50A,

For more product information by email, click here