Share  
Print  
EATON BUSSMANN

60A Fast Acting Melamine Fuse with 600VAC Voltage Rating; KTS-R Series

Hover over image to magnify
Fuse,RK1,Kts-R,60A,600VAC,
Fuse,RK1,Kts-R,60A,600VAC,

#924486-6 | Pkg Qty: 1

$98.72 pkg | $98.72 ea

Drop Ship Item

Shipping to 60045

Technical Specifications

Key Specifications
AC Voltage Rating
600 VAC
Indicating
No
Amperage
60 A
Indicating / Nonindicating
Nonindicating
Body Material
Melamine
Interrupt Rating
200kA at 600VAC
Body Style
Cylindrical
Item
Fuse
Brand
EATON BUSSMANN
Length
5-1/2 in.
Class
RK1
Mfr. Part Number
KTS-R-60
DC Voltage Rating
Not Rated
Package Quantity
1
Diameter
13/16 in.
Rejection / Nonrejection
Rejection
Element
Single
Series
Kts-R
Functionally Equal To
Mersen/Ferraz Shawmut A6K-R, Littelfuse KLSR
Shipping Weight
.35 lb.
Fuse Amps
60A
Speed
Fast Acting
Fuse Holder Code
Q
Type
Low Voltage
Fuse Speed
Fast Acting
Voltage Rating
600 VAC
Fuse Voltage Rating
600 VAC
General
Compatible Fuse Block Series
1BR, R600, RM250, RM251, RM252, RM254, RM256, RM600, RM601, RM602, RM604, RM606
Fuse Size
5-1/2 in L x 13/16 in dia
Equivalent Series
A6K-R, KLSR, KTS-R
Standards
CE, UL 248-12 Guide JDDZ, File E4273, CSA C22.2 No. 248.12, Class 1422-02, File 53787
Fits Fuse Block Style
Rejection
Visual Indication
Nonindicating

Product Description

Fast-acting, nonindicating UL Class RK1 fuses open within seconds of being exposed to overloads and short circuits. Also called fast-blow Class RK1 fuses, they are highly sensitive to changes in current flow and don't tolerate temporary overload currents or power surges. They have no indicator for identifying a blown fuse, so they're sometimes used with an indicating fuse block or cover.

UL Class RK1 fuses are more current-limiting than RK5 fuses to react more quickly to overcurrent. These fuses are the same size as Class H and K fuses, but have a rejection feature that prevents an accidental downgrade from a current-limiting system. Their modified terminals ensure a match with the rejection clips in Class R fuse holders that prevent the installation of fuses with a lower interrupting capacity. They're typically used in newer equipment, but can also be used with a Class H fuse holder to upgrade older installations from Class H or K fuses for improved overcurrent protection. These fuses are current-limiting to prevent electrical damage by disconnecting circuits before they're exposed to the full magnitude and duration of an overcurrent.

Item Barcode
9244866
Fuse,RK1,Kts-R,60A,600VAC,
 NameItemDescription
Grainger DropshipGrainger Dropship1CX15Fuse,RK1,KTS- R,60A,600VAC,
UNSPSC CODESUNSPSC CODES39121625
VMRS (ATA) CODESVMRS (ATA) CODES034-004-009Fuse,RK1,KTS- R,60A,600VAC,

For more product information by email, click here