| Home > Products > Chemicals & Paint > MSDS Sheets > MSDS 7568 -- [Back] | |||
|
MSDS 7568 7568: Copper Anti-Seize 8OZ. [1]7583: Copper Anti-Seize Brush Top [1] (DISCONTINUED) MSDS Last updated: 04/01/2008
MSDS DOCUMENT
Product Dynatex(R) 49582 Copper Anti-Seize & Lubricating Compound
1. Chemical Product and Company Identification
Trade Name of this Product Dynatex(R) 49582 Copper Anti-Sieze & Lubricating
Compound MSDS ID DYN49582
Manufacturer Phone Number
Dynatex Inc. (270) 769-3385
350 Ring Road Emergency Phone
Elizabethtown, KY 42701 CHEMTREC (800) 424-9300
Revision Date 6/25/2005
Health: 1
Fire: 1
Reactivity: 1
Specific PPE: B
2. Composition and Information Ingredients
Ingredient CAS Number Weight % ACGIH TLV PEL STEL
Petroleum oil 64741-96-4 50%-60%
NJTSRN Trade Secret 15%-20%
80100362-5013P
NJTSRN Trade Secret 15%-20%
80100362-5012P
Copper, as fume or 7440-50-8 5%-10% 1 mg/m 1 mg/m
dust
NJTSRN Trade Secret 1%-5%
80100362-5004P
Graphite (natural) 7782-42-5 1%-5% 2.0 mg/m resp dust 5 mg/m
NJTSRN Trade Secret 0.5%-1%
80100362-5018P
NJTSRN Trade Secret 0.5%-1%
80100362-5014P
3. Hazard Identification
Symptoms of Overexposure
May cause irritation to eyes and skin on sensitive individuals.
Existing Conditions Aggravated by Exposure
Prolonged or repeated contact may produce mild skin irritation and
inflammation. Personnel with pre-existing skin disorder should avoid
contact.
4. First Aid Information
Eye Contact
Immediately flush eyes with water for at least 15 minutes. Get medical
attention if irritation develops.
Skin Contact
Wash with soap and water. If irritation occurs, seek medical attention.
Inhaltion
Remove to fresh air. If symptoms persist, obtain appropriate
medical attention.
Ingestion
Do not induce vomiting. Keep warm. Get medical attention.
5. Fire Fighting Measures
Flash Point 420F
FP Method COC
Extinguishing Media
Carbon Dioxide, Dry Chemical,Foam
Hazardous Decomposition Products
Thermal breakdown of this product druing fire or very high heat
conditions may evolve the following hazardous decomposition products:
Carbon Dioxide
Carbon Monoxide
Trace metal oxides
Special Fire Fighting Procedures
Fight like a fuel oil fire. Cool fire exposed containers with water
spray. Fire fighter should wear OSHA/NIOSH approved self-contained
breathing apparatus.
Unusual Fire or Explosion Hazards
None known
6. Accidental Release Measures
Steps to be taken in case of spill or release
Stop flow, scrape, wipe, mop up or absorb with diatomaceous earth
or other inert material.
Disposal should be in accordance with local, state, and federal regulations.
7. Handling and Storage
Handling
Spills may cause slippery floors. Proper footwear required.
Remove contaminated clothing and launder before reuse.
Wash hands with soap and water before eating, drinking or smoking.
Discard contaminated leather gloves and shoes.
Storage
Avoid storage near open flame or other sources of ignition.
8. Exposure Controls and Personal Protection
Eye Protection
Safety goggles or glasses with side shields are recommended.
Skin Protection
Use neoprene, nitrile, or rubber gloves to prevent skin contact.
Respiratory Protection
No special requirements under ordinary conditions of use and with
adequate ventilation.
Other Protective Clothing or Equipment
None under normal use: however, use of solvent resistant aprons or
other clothing is recommended. Use of chemically resistant boots is
recommended.
Other Precautions
Have emergency shower and eye wash available.
9. Physical and Chemical Properties
Physical State Paste
Specific Gravity 1.27
Color/Appearance Copper color
Odor Petroleum odor
Boiling/Cond. Point Not applicable
Melting/Freezing Point None
Solubility Insoluble in water
Evaporation Rate Not applicable
Percent Volatile None
Vapor Density Not applicable
Vapor Pressure Not applicable
Note
The above information is not intended for use in preparing product
specifications. Contact Accumetric LLC before writing specifications.
10. Stability and Reactivity
Chemical Stability
Stable
Hazardous Polymerization
Will not occur
Materials to Avoid / Incompatibilities
Keep away from strong oxidizing agents.
Conditions to Avoid
Do not heat above flash point. Do not weld.
11. Toxicological Information
Carcinogenicity
This product is not known to be a carcinogen.
Sensitizer
This product is not known to be a sensitizer.
Mutagenicity
This product is not known to be a mutagen.
Teratogenicity
This product is not known to be a teratogen.
Reproductive Toxin
This product is not known to be a reproductive toxin.
12. Ecological Information
Environmental Fate and Distribution
Complete information is not yet available.
Environmental Effects
Complete information is not yet available.
Fate and Effects in Waste Water Treatment Plants
Complete information is not yet available.
13. Disposal Considerations
Waste Disposal Method
We make no guarantee or warranty of any kind that the use or disposal of
this product complies with all local, state, or federal laws.
It is also the obligation of each user of the product mentioned herein
to determine and comply with the requirements of all applicable statutes.
This product is not known to be regulated under RCRA regulations, but
contains SARA regulated substances. Disposal of unused portions of this
product and process waste containing this product should be done only
after a careful evaluation and in compliance with all federal, local
and state laws.
14. Transportation Information
15. Regulatory information
The contents of this MSDS comply with the OSHA Hazard Communication
Standard 29 CFR 1910.1200.
TSCA Status
All chemical substances in this material are included on or exempted
from listing on the TSCA Inventory of Chemical Substances.
SARA Title III Section 302 Extremely Hazardous Substances.
None
SARA Title III Section 304 CERCLA Hazardous Substances.
Copper Powder (7440-50-8)
SARA Title III Section 313 Toxic Chemicals
Copper Powder (7440-50-8)
California Proposition 65
This product contains the following chemical(s) listed by the State of
California under the Safe Drinking Water and Toxic Enforcement Act of
1986 (Proposition 65) as being known to cause cancer, birth defects or
other reproductive harm:
None known.
New Jersey
Copper Powder (7440-50-8)
Pennsylvania
Graphite Powder (7782-42-5)
Copper Powder (7440-50-8)
16. Other Information
Disclaimer
The data contained herein is based upon information that Accumetric
LLC believes to be reliable. Users of this product have the responsibility
to determine that suitability of use and to adopt all necessary precautions
to ensure the safety and protection of property and persons involved
in said use. All statements to suggestions are made without warranty,
expressed or implied, regarding the accuracy of the information, the
hazards connected with the use of the material or the results to be
obtained from the use therof.
The information contained in this MSDS was obtained from current and reliable sources, however, the data is provided without any warrenty, expressed or implied, regarding its correctness or accuracy. Since the conditions or handling, storage and disposal of this product are beyond the control of Imperial Supplies LLC, Imperial will not be responsible for loss, injury, or expense arising out of the products improper use. No warranty, expressed or inferred, regarding the product described in this MSDS shall be created or inferred by any statement in this MSDS. Various government agencies may have specific regulations regarding the transportation, handling, storage, use, or disposal of this product which may not be covered by this MSDS. The user is responsible for full compliance. For more product information by email, click here Imperial Supplies LLC does not provide services and products outside the United States |