| Home > Products > Chemicals & Paint > MSDS Sheets > MSDS 4014 -- [Back] | |||
|
MSDS 4014 4014: Paint And Resin Hand Cleaner [1] (DISCONTINUED)4014-2: 15 Oz. Resin Hand Cleaner [2] (DISCONTINUED) MSDS Last updated: 12/29/2004
MATERIAL SAFETY DATA SHEET
***SECTION I. CHEMICAL PRODUCT AND COMPANY IDENTIFICATION***
MANUFACTURER'S NAME: LOCTITE CORP.
MANUFACTURER'S ADDRESS: 1001 TROUT BROOK CROSSING
CITY/STATE/ZIP: ROCKY HILLS, CT 06067
DISTRIBUTOR'S NAME: IMPERIAL SUPPLIES LLC
DISTRIBUTOR'S ADDRESS: 789 PACKER DRIVE
CITY/STATE/ZIP: GREEN BAY WI 54307
INFORMATION PHONE NUMBER: 800-558-2808
EMERGENCY PHONE NUMBER: 800-255-3924 (CHEM-TEL)
PRODUCT NAME: PARR P&R 60 MO
IMPERIAL PART NUMBER: 4014 & 4014-2
PRODUCT TYPE: HAND CLEANER
UPDATED: 1/8/2002
***SECTION II. COMPOSITION, INFORMATION ON INGREDIENTS***
INGREDIENTS CAS NO. %
--------------------------------------------------------------------------------
WATER 7732-18-5 50-70
GLUTARIC ACID ESTER 1119-40-0 15-30
PUMICE 1332-09-8 10-15
MINERAL OIL 64742-65-0 2-7
SUCCINIC ACID ESTER 106-65-0 1-15
DIMETHYL ADIPATE 627-93-0 1-15
NONIONIC SURFACTANT 9016-45-9 0.1-1
PROPYLENE GLYCOL 0057-55-6 0.1-5
SILICA, QUARTZ 014808-60-7 0.1-1
INGREDIENTS WHICH HAVE EXPOSURE LIMITS
EXPOSURES LIMITS (TWA) ACGIH OSHA OTHER
INGREDIENTS (TLV) (PEL)
--------------------------------------------------------------------------------
GLUTARIC ACID ESTER NONE NONE 1.5 PPM
PUMICE 10 MG/M3 (IHNAL) 15 MG/M3 (TOTAL) NONE
3 MG/M3 (RESP) 5 MG/M3 (RESP)
MINERAL OIL 5 MG/M3 TWA MIST 5 MG/M3 TWA MIST NONE
SUCCINIC ACID ESTER NONE NONE 1.5 PPM
DIMETHYL ADIPATE NONE NONE 1.5 PPM
SILICA, QUARTZ 0.05 MG/M3 TWA 0.1 MG/M3 TWA NONE
RESPIRABLE DUST RESPIRABLE DUST
EXPOSURES LIMITS (STEL) ACGIH OSHA
INGREDIENTS (TLV) (PEL)
--------------------------------------------------------------------------------
MINERAL OIL 10 MG/M3 MIST NONE
***SECTION III. HAZARDS IDENTIFICATION***
TOXICITY: MAY CAUSE IRRITATION OF EYES AND UPPER RESPIRATORY
TRACTS.
PRIMARY ROUTES
OF ENTRY: EYE CONTACT, INGESTION AND INHALATION.
SIGNS AND SYMPTOMS
OF OVEREXPOSURE: IRRITATION OF EYES, SKIN, OR UPPER RESPIRATORY TRACT.
EXISTING CONDITIONS
AGGRAVATED BY EXPOSURE: NONE KNOWN.
LITERATURE REFERENCED CARCINOGEN
INGREDIENTS TARGET ORGAN AND OTHER HEALTH EFFECTS NTP IARC OSHA
--------------------------------------------------------------------------------
WATER NTO NO NO NO
GLUTARIC ACID ESTER OLF NO NO NO
PUMICE NTO NO NO NO
MINERAL OIL NTO NO NO NO
SUCCINIC ACID ESTER IRR NO NO NO
DIMETHYL ADIPATE OLF NO NO NO
NONIONIC SURFACTANT ALG IRR NO NO NO
PROPYLENE GLYCOL IRR NO NO NO
SILICA, QUARTZ LUN SOM YES 2A NO
--------------------------------------------------------------------------------
ABBREVIATIONS:
2A PROBABLY CARCINOGENIC TO HUMANS ALG ALLERGEN
IRR IRRITANT LUN LUNG
NTO NOT TARGET ORGANS OLF OLFACTORY
SOM EVIDENCE OF SOME CARCINOGENICITY
***SECTION IV. FIRST AID MEASURES***
INGESTION: DO NOT INDUCE VOMITING. CALL PHYSICIAN IMMEDIATELY.
INHALATION: REMOVE TO FRESH AIR. IF SYMPTOM PERSIST, OBTAIN MEDICAL
ATTENTION.
SKIN CONTACT: FLUSH WITH WATER
EYE CONTACT: FLUSH WITH WATER FOR AT LEAST 15 MINUTES. CALL PHYSICIAN
IMMEDIATELY.
***SECTION V. FIRE FIGHTING MEASURES***
FLASH POINT: >200 DEGREES F
METHOD: PENSKY-MARTENS CLOSED CUP
RECOMMENDED
EXTINGUISHING AGENTS: CARBON DIOXIDE, CHEMCIAL POWDER.
SPECIAL FIRE FIGHTING
PROCEDURES: NOT AVAILABLE
HAZARDOUS PRODUCTS FORMED BY
FIRE OR THERMAL DECOMPOSITION: IRRITATING ORGANIC VAPORS, OXIDES OF CARBON
UNUSUAL FIRE OR
EXPLOSION HAZARDS: NONE
EXPLOSIVE LIMITS
(%BY VOLUME IN AIR): LOWER: NOT AVAILABLE
(%BY VOLUME IN AIR): UPPER: NOT AVAILABLE
***SECTION VI. ACCIDENTAL RELEASE MEASURES***
STEPS TO BE TAKEN IN
CASE OF SPILL OR LEAK: RINSE AWAY WITH WASTER OR WIPE UP WITH A TOWEL.
***SECTION VII. HANDLING AND STORAGE***
SAFE STORAGE: HAND CLEANER SHOULD BE STORED BETWEEN 40 DEGREES F AND 100
DEGREES F.
(CONTACT LOCTITE CUSTOMER SERVICE 1-800-243-4874 FOR SHELF LIFE INFORMATION)
HANDLING: FOLLOW ALL GENERAL SAFETY PRECAUTIONS. KEEP AWAY FROM
CHILDERN.
***SECTION VIII. EXPOSURE CONTROLS, PERSONAL PROTECTION***
EYES: NONE NORMALLY NEEDED, BUT SAFETY GLASSES OFFER INCREASED
PROTECTION.
SKIN: NONE NORMALLY NEEDED.
VENTILATION: SOME LOCAL VENTILATION MAY BE DISIRED FOR PROLONGED EXPOSURE IN A
CONFINED AREEA.
RESPIRATORY: NOT AVAILABLE
SEE SECTION II. FOR EXPOSURE LIMITS.
***SECTION IX. PHYSICAL AND CHEMICAL PROPERTIES***
APPEARANCE: GREY LOTION WITH MINERAL SCRUBBERS
ODOR: FLORAL
BOILING POINT: NO AVAILABLE
PH: 4.5-5.5
SOLUBILITY IN WATER: SOLUBLE
SPECIFIC GRAVITY: APPROXIMATELY 1.07
VOLATILE ORGANIC COMPOUND
(EPA METHOD 24): APPROXIMATELY 31.87%; 341 GRAMS PER LITER
VAPOR PRESSURE: NOT AVAILABLE
VAPOR DENSITY: NOT AVAILABLE
EVAPORATION RATE
(ETHER=1): NOT AVAILABLE
***SECTION X. STABILITY AND REACTIVITY***
STABILITY: STABLE
HAZARDOUS POLYMERIZATION: WILL NOT OCCUR
INCOMPATIBILITY: STRONG OXIDIZERS, ACIDS, ALKALINES
CONDITIONS TO AVOID: NOT AVAILABLE
HAZARDOUS DECOMPOSITION
PRODUCTS(NON-THERMAL): NONE
***SECTION XI. TOXICOLOGICAL INFORMATION***
SEE SECTION III.
***SECTION XII. ECOLOGICAL INFORMATION***
NO DATA AVAILABLE
***SECTION XIII. DISPOSAL CONSIDERATIONS***
RECOMMENDED METHODS
OF DISPOSAL: DISPOSE OF UNCONTAMINATED MATERIAL THROUGH SEWAGE
SYSTEM WITH PERMISSIOIN OF THE AUTHORITY RESPONSIBLE FOR
THAT SYSTEMS. FOLLOW EPA AND LOCAL REGULATIONS.
EPA HAZARDOUS WASTE
NUMBER: NH- NOT A RCRA HAZARDOUS WASTE MATERIAL.
***SECTION XIV. TRANSPORTATION INFORMATION***
DOT (49 CFR 172)
DOMESTIC GROUND TRANSPORT
PROPER SHIPPING NAME: UNRESTRICTED
HAZARD CLASS OR DIVISION: UNRESTRICTED
IDENTIFICATION NUMBER: NONE
MARINE POLLUTANT: NONE
IATA
PROPER SHIPPING NAME: UNRESTRICTED
CLASS OR DIVISION: UNRESTRICTED
UN OR ID NUMBER: NONE
***SECTION XV. REGULATORY INFORMATION***
CA PROPOSITION 65: NO CALIFORNIA PROP 65 CHEMICALS ARE KNOWN TO BE PRESENT
AT OR ABOVE THE NO SIGNIFICANT RISK LEVEL.
***SECTION XVI. OTHER INFORMATION***
ESTIMATED NFPA (R) CODE:
HEALTH HAZARD: 1
FIRE HAZARD: 1
REACTIVITY HAZARD: 0
SPECIFIC HAZARD: DOES NOT APPLY
ESTIMATED HMIS (R) CODE:
HEALTH HAZARD: 1
FLAMMABILITY HAZARD: 1
REACTIVITY HAZARD: 0
PERSONAL PROTECTION: SEE SECTION VIII.
NFPA IS A REGISTERED TRADEMARK OF THE NATIONAL FIRE PROTECTION ASSN.
HMIS IS A REGISTERED TRADEMARK OF THE NATIONAL PAINT AND COATINGS ASSN.
PREPARED BY: STEPHAN REPETTO
TITLE: RESEARCH CHEMIST - HEALTH & REGULATORY AFFAIRS
COMPANY: LOCTITE CORP., 1001 TR BR CR, ROCKY HILL CT 06067
(24 HR) PHONE: 860-571-5100
REVISION DATE: JANUARY 27, 1999 REVISION: 0009
The information contained in this MSDS was obtained from current and reliable sources, however, the data is provided without any warrenty, expressed or implied, regarding its correctness or accuracy. Since the conditions or handling, storage and disposal of this product are beyond the control of Imperial Supplies LLC, Imperial will not be responsible for loss, injury, or expense arising out of the products improper use. No warranty, expressed or inferred, regarding the product described in this MSDS shall be created or inferred by any statement in this MSDS. Various government agencies may have specific regulations regarding the transportation, handling, storage, use, or disposal of this product which may not be covered by this MSDS. The user is responsible for full compliance. For more product information by email, click here Imperial Supplies LLC does not provide services and products outside the United States |